D. Barker, J. Kissel, J. Rollins
WP 8070
WP 8077
We've compiled, installed, and restarted the following changes to CAL models:
h1calex
(1) Removed the last of the old hardware injection infrastructure (top-level model change WP 8077).
(2) Added switch for FORCE COEFF calculation check (by changing PCAL_MASTER)
h1caley
(2) Added switch for FORCE COEFF calculation check (by changing PCAL_MASTER)
h1calcs
(3) Installed whitening (high pass) filters to change dynamic range of the signals going in to the CFTD actuator path (just updated the CAL_CS_MASTER library part; see details in LLO:42961)
(4) Added additional EPICS records to calculate the time dependence of the sensing function's optical spring parameters from the ~15-20 Hz PCAL line (instead of needing the additional ~8Hz line).
As an additional step to item (4), we added the following
H1:CAL-CS_TDEP_PCAL_LINE1_REF_A_PUM_IMAG
H1:CAL-CS_TDEP_PCAL_LINE1_REF_A_PUM_REAL
H1:CAL-CS_TDEP_PCAL_LINE1_REF_A_TST_IMAG
H1:CAL-CS_TDEP_PCAL_LINE1_REF_A_TST_REAL
H1:CAL-CS_TDEP_PCAL_LINE1_REF_A_UIM_IMAG
H1:CAL-CS_TDEP_PCAL_LINE1_REF_A_UIM_REAL
H1:CAL-CS_TDEP_PCAL_LINE1_REF_C_NOCAVPOLE_IMAG
H1:CAL-CS_TDEP_PCAL_LINE1_REF_C_NOCAVPOLE_REAL
H1:CAL-CS_TDEP_PCAL_LINE1_REF_D_IMAG
H1:CAL-CS_TDEP_PCAL_LINE1_REF_D_REAL
to the GDS broadcaster.
One more change that we'll install tomorrow in support of (1)
h1iscex
(5) We removed the ODC block and all IPC senders and receivers in support of item (1) from h1pcalex.
For item (1), I changed and committed:
/opt/rtcds/userapps/release/cal/h1/models/
h1calex.mdl
h1caley.mdl
For item (2) I changed and committed:
/opt/rtcds/userapps/release/cal/common/models/
PCAL_MASTER.mdl
For items (3) and (4), I changed and committed:
/opt/rtcds/userapps/release/cal/common/models/
CAL_CS_MASTER.mdl
For item (5), I changed and committed:
/opt/rtcds/userapps/release/isc/h1/models/
h1iscex.mdl