Reports until 11:23, Monday 04 February 2019
H1 AOS
jeffrey.kissel@LIGO.ORG - posted 11:23, Monday 04 February 2019 - last comment - 13:59, Monday 04 February 2019(46758)
h1calcs, h1calex, h1caley model changes installed TODAY (ahead of Tuesday Maintenance, due to weather and low IFO impact)
D. Barker, J. Kissel, J. Rollins
WP 8070
WP 8077

We've compiled, installed, and restarted the following changes to CAL models:
h1calex
(1) Removed the last of the old hardware injection infrastructure (top-level model change WP 8077).
(2) Added switch for FORCE COEFF calculation check (by changing PCAL_MASTER)

h1caley
(2) Added switch for FORCE COEFF calculation check (by changing PCAL_MASTER)

h1calcs
(3) Installed whitening (high pass) filters to change dynamic range of the signals going in to the CFTD actuator path (just updated the CAL_CS_MASTER library part; see details in LLO:42961)
(4) Added additional EPICS records to calculate the time dependence of the sensing function's optical spring parameters from the ~15-20 Hz PCAL line (instead of needing the additional ~8Hz line).

As an additional step to item (4), we added the following 
    H1:CAL-CS_TDEP_PCAL_LINE1_REF_A_PUM_IMAG
    H1:CAL-CS_TDEP_PCAL_LINE1_REF_A_PUM_REAL
    H1:CAL-CS_TDEP_PCAL_LINE1_REF_A_TST_IMAG
    H1:CAL-CS_TDEP_PCAL_LINE1_REF_A_TST_REAL
    H1:CAL-CS_TDEP_PCAL_LINE1_REF_A_UIM_IMAG
    H1:CAL-CS_TDEP_PCAL_LINE1_REF_A_UIM_REAL
    H1:CAL-CS_TDEP_PCAL_LINE1_REF_C_NOCAVPOLE_IMAG
    H1:CAL-CS_TDEP_PCAL_LINE1_REF_C_NOCAVPOLE_REAL
    H1:CAL-CS_TDEP_PCAL_LINE1_REF_D_IMAG
    H1:CAL-CS_TDEP_PCAL_LINE1_REF_D_REAL
to the GDS broadcaster.

One more change that we'll install tomorrow in support of (1)
h1iscex
(5) We removed the ODC block and all IPC senders and receivers in support of item (1) from h1pcalex.

For item (1), I changed and committed:
/opt/rtcds/userapps/release/cal/h1/models/
    h1calex.mdl
    h1caley.mdl

For item (2) I changed and committed:
/opt/rtcds/userapps/release/cal/common/models/
    PCAL_MASTER.mdl

For items (3) and (4), I changed and committed:
/opt/rtcds/userapps/release/cal/common/models/
    CAL_CS_MASTER.mdl

For item (5), I changed and committed:
/opt/rtcds/userapps/release/isc/h1/models/
    h1iscex.mdl

Images attached to this report
Comments related to this report
jeffrey.kissel@LIGO.ORG - 12:45, Monday 04 February 2019 (46763)
J. Kissel

I've changed common PCAL MEDM screen to support the new FORCE_COEFF_CHECK_SW. Attached shows switch functionality ON vs OFF.

Changes committed to 
/opt/rtcds/userapps/release/cal/common/medm/
    PCAL_END_FORCE_COEFF.adl
Images attached to this comment
jeffrey.kissel@LIGO.ORG - 13:59, Monday 04 February 2019 (46768)
J. Kissel

Modified MEDM screen for EPICs records addition of PCAL_LINE1 channels described above (EP19-23).

Changes committed to 
/opt/rtcds/userapps/release/cal/common/medm/
    CAL_CS_TDEP_EPICS_RECORDS.adl

Screenshot attached.
Images attached to this comment