Displaying report 1-1 of 1.
Reports until 15:45, Monday 04 February 2019
H1 CDS (DAQ)
david.barker@LIGO.ORG - posted 15:45, Monday 04 February 2019 (46774)
Monday morning restarts.

Jamie, Jeff K, Jonathan, Nutsinee, Dave:

To get a jump on some restarts while we had high winds, the following were restarted Monday morning:

h1calcs, h1calex and h1caley models were restarted.

h1odcmaster was removed from the DAQ (the master file).

The requested DAQ channels were added to the DAQ-GDS broadcaster.

DAQ was restarted. Several problems were found:

We removed SQZ_PLL from the GRD INI file, and I removed the duplicated GDS channels.

DAQ was restarted a second time. Unfortunately H1EDCU_GRD.ini had been created with the new guardian version, which put in additional status channels which won't exists on the running system until tomorrow's upgrade. We will run with a red EDCU until that time. I also found an ODCMASTER entry in H1EDCU_DAQ.ini which I had missed, this will also go in tomorrow.

h1odcmaster was removed in the rtsystab file, the model was stopped on h1oaf0.

I removed h1odcmaster from the following MEDM Overview screens: CDS, IPC, DAQ.

DAQ Data Concentrator log level. Jonathan changed the log level on h1dc0 from 2 to 5.

(*) note to self, my script which checks for duplicate channels in the DAQ needs to also check the Broadcaster file

Displaying report 1-1 of 1.