J. Kissel 8077 Reconciling SDFs prior to the h1iscex/h1iscey model restarts, I've accepted QPD offsets that were last changed on Jan 27th 2019. see attached screenshots.
Some of h1susetmx and h1susetmy L2 GAINs and associated TRAMPs were accepted.
Channel new (old)
H1:SUS-ETMX_L2_DRIVEALIGN_P2L_GAIN 2.647711781 (2.655)
H1:SUS-ETMX_L2_DRIVEALIGN_Y2L_GAIN 3.2292331724 (2.7)
H1:SUS-ETMX_L2_LOCK_P_GAIN 1.05 (1.04)
H1:SUS-ETMX_L2_LOCK_Y_GAIN 1.0 (0.99)
H1:SUS-ETMY_L2_DRIVEALIGN_P2L_GAIN 3.5500448048 (3.4)
H1:SUS-ETMY_L2_DRIVEALIGN_Y2L_GAIN 0.8850832254 (1.95)
H1:SUS-ETMY_L2_LOCK_P_GAIN 0.94 (0.96)
H1:SUS-ETMY_L2_LOCK_Y_GAIN 1.0 (1.01)
ETMX sus callines were disabled (because we haven't successfully get back to EX-only), and ETMY sus callines were enabled instead, and were accepted.
H1:SUS-ETMX_L1_CAL_LINE_CLKGAIN 0
H1:SUS-ETMX_L2_CAL_LINE_CLKGAIN 0
H1:SUS-ETMY_L1_CAL_LINE_CLKGAIN 150
H1:SUS-ETMY_L2_CAL_LINE_CLKGAIN 400