DSOFT P gain increase

Sheila, Georgia, Jenne, Marie

We modified the DSOFT P loop today:

The measurement might be compatible with a reduction of the cross-over frequency, but the phase shift is small compared to what I expected (see figure 1). We might need to add a roll-off in M0 to further reduce the cross-coupling.

We lost lock tonight several times due to dtt excitation, but the good news is that we relocked fast each time to low noise without seeing any oscillation.The increase of DSOFT P gain is probably helping.