Laser Status:
Front End Power is 31.53W (should be around 30 W)
70W Output Power is 71.57W
Front End Watch is RED
70W Watch is GREEN
PMC:
It has been locked 0 days, 0 hr 44 minutes (should be days/weeks)
Reflected power = 10.69Watts
Transmitted power = 53.62Watts
PowerSum = 64.31Watts.
FSS:
It has been locked for 0 days 0 hr and 42 min (should be days/weeks)
TPD[V] = 2.033V (min 0.9V)
ISS:
The diffracted power is around 2.7%
Last saturation event was 0 days 0 hours and 33 minutes ago (should be days/weeks)
Possible Issues:
PSL chiller was swapped today, so it had come back recently when this report made.