daniel.vander-hyde@LIGO.ORG - posted 17:47, Sunday 17 February 2019 - last comment - 16:15, Monday 18 February 2019(46975)
morning/afternoon locking
Images attached to this report
Comments related to this report
sheila.dwyer@LIGO.ORG - 16:15, Monday 18 February 2019 (46981)

This lock lasted more than 20 hours.  

A bruco scan is available here.  There is a lot of coherence with the ETMX L1 FASTIMON channels, which are just seeing DARM, which I've now added to the excluded channels list.  Other than that we have a few things of interest:

  • ASC noise below 30 Hz ITMY_L2_NOISEMON_LL
  • SRCL at 27.7 Hz 
  • Line coherent with magnetometers in the remote racks at EX around 73.5 Hz
  • HAM5/6 septum accelerometers at 90 Hz.  This had been peaking above DARM, but the peak seems to have been reduced sometime between Feb 3rd and now.
  • Laser noise at high frequencies 