Craig, Georgia
Today we locked the OMC on single-bounce carrier with 20 W input and injected large sideband intensity noise to measure the modulation depths for locking and low noise settings.
Results
Sideband     Locking EOM Driver Slider Value [dBm]     Low Noise EOM Driver Slider Value [dBm]     Locking Mod Depth     Low Noise Mod Depth
---------------------------------------------------------------------------------------------------------------------------------------------
9 MHz                                   23.4                                        20.4                       0.190                   0.160
45 MHz                                  27.0                                        24.0                       0.219                   0.182
Method
A simple comparison of the carrier and sideband RINs when injecting.  
RIN0(f) = Γ2 RINsb(f)
We know that we can trust the 9 and 45 MHz RFAM monitors when we inject high broadband noise in the EOM driver.  
At the same time, if we inject enough sideband RFAM, the carrier RIN should show through in the OMC transmission.
All injections were amplitude=10, ellip("BandPass",4,1,30,5000) through the LSC EXTRA AO 3, which is connected to the front of the drivers.
Reason
We've been running several 9 MHz RIN tests.  It is good to know, for some high level of sideband RIN, the level of carrier RIN we expect. 
Old EOM Driver alogs
Koji installation
Daniel boost