FAMIS11001
Laser Status:
Front End Power is 32.74W (should be around 30 W)
70W Output Power is 69.49W
Front End Watch is RED
70W Watch is GREEN
PMC:
It has been locked 0 days, 0 hr 1 minutes (should be days/weeks)
Reflected power = 11.57Watts
Transmitted power = 53.15Watts
PowerSum = 64.72Watts.
FSS:
It has been locked for 0 days 0 hr and 0 min (should be days/weeks)
TPD[V] = 0.006749V (min 0.9V)
ISS:
The diffracted power is around 2.8%
Last saturation event was 0 days 0 hours and 0 minutes ago (should be days/weeks)
Possible Issues: Peter is currently out at the PSL, tweaking the FSS alignment.