Reports until 16:53, Wednesday 27 February 2019
H1 ISC
jenne.driggers@LIGO.ORG - posted 16:53, Wednesday 27 February 2019 (47168)
Green initial alignment references set for new spot positions

I have reset the green initial alignment spot positions, so that initial alignment will bring us back to the place that we explored on Monday that is about 7mm higher on ITMY than we have been, so that we're splitting the difference between 2 different point absorbers on ITMY.  See alog 47117 for the spot exploration.

Still not done is alignment of the ALS beatnotes with this new alignment.