The peaks at 206Hz and 234Hz are gone. I guess the PBS did something good. The other two lines are still persistent. One at 177.7Hz got worse after I closed and reopened the beam diverter after a long lock (orange trace for ASQZ, cyan for SQZ). Compare to purple trace that I took right when I got in the control room. The line at 262Hz got worse after the beam diverter closed/opened but got better after sometime passed (dark purple). Maybe this suggests something mechanical? The next thing to do is to check the coherence with accelerometers.
Note that I kept the phase the same as last sqz measurement and I didn't optimized the nlg before I took this measurement (temperature setting was the same as last time).

You could try taking another spectrum with the noise eater turned off. At LLO we found the noise eater was adding a peak at ~200Hz to our CLF (aLOG 43780).