Displaying report 1-1 of 1.
Reports until 21:48, Wednesday 27 February 2019
H1 AOS
daniel.vander-hyde@LIGO.ORG - posted 21:48, Wednesday 27 February 2019 - last comment - 11:01, Thursday 28 February 2019(47175)
Notch at 17.75 Hz and resonance at 17.80 Hz in MICH OLTF

Craig, Stefan, Danny

Images attached to this report
Comments related to this report
craig.cahillane@LIGO.ORG - 00:06, Thursday 28 February 2019 (47178)
Comparison of the MICH feedforward TF with and without the beamsplitter resonance TF applied.
Non-image files attached to this comment
jeffrey.kissel@LIGO.ORG - 11:01, Thursday 28 February 2019 (47187)SYS
I dunno if it's on the "liens" list or not, but this is one more reason to consider Bounce and Roll Mode dampers (BRDs) for the Beam Splitter.

In general, the idea would be to make the ISC / global plants that involve the beam splitter a little more easy to handle.
- ASC control design wouldn't have to deal with as much phase loss from this plant feature
- We wouldn't have to worry as much about kicking up these modes after a lock loss or during lock acquisition
- We could increase the MICH LSC loop gain.
Displaying report 1-1 of 1.