Had to change some parameters on the new squeezer CLF photodiode (S1900052) that was posted yesterday (Log entry 47171) due to me making a mistake. 1. Moved resonant inductor to the right location in the circuit to have a measure of DC photocurrent (dumb mistake) 2. Rechecked the resonant frequency and Q. New Q = 29. Had to adjust the trimming capacitor a little bit for 6.25MHz Fc 3. Installed a 10k resistor into the DC transimpedance stage replacing the 100 ohm resistor that was previously installed. Remeasured output noise, resonant response, Q. Calculated new SNEP = 9.5uA. Confirmed by introducing ~10uA photocurrent and observing 3dB increase in noise.