J. Kissel, S. Dwyer, After Sheila fixed a few hiccups in the NLN_CAL_MEAS state's return to NOMINAL_LOW_NOISE in the ISC_LOCK guardian, I was able to gather all measurements necessary for updating the actuation function of the calibration. I was tuning the amplitude in sensing function's DARM OLG sweep to get better coherence between 5 - 20 Hz (to resolve detuning), aborted the measurement and we lost lock [it was a swept sine, and yes, it had a 3 sec ramp down time. I was actively watching the ASDs of ETMX digital requests to the DAC and we were no where close to saturating]. Anyways -- analysis to come, but the data lives here: /ligo/svncommon/CalSVN/aligocalibration/trunk/Runs/O3/H1/Measurements/FullIFOActuationTFs/ 2019-03-01_H1SUSETMX_L1_iEXC2DARM_25min.xml 2019-03-01_H1SUSETMX_L1_PCAL2DARM_8min.xml 2019-03-01_H1SUSETMX_L2_iEXC2DARM_17min.xml 2019-03-01_H1SUSETMX_L2_PCAL2DARM_8min.xml 2019-03-01_H1SUSETMX_L3_iEXC2DARM_8min.xml 2019-03-01_H1SUSETMX_L3_PCAL2DARM_8min.xml Note that during these measurements, one *has* to turn of the Alignment Dither Loop system (namely DOFs 3 4 and 5), which controls the drift of the Y Arm (roughly equivalent to the SOFT DOF). With the loops OFF, the alignment does drift slowly, on a ~20 minute time-scale. As such, given the length of my measurements, I went back from NLN_CAL_MEAS to NOMINAL_LOW_NOISE in between clusters of measurements and waited there for the ADS error signals to steer back towards zero (which takes about 5 minutes), then switched back to NLN_CAL_MEAS and resumed measurements. And although the data is meaningless, the amplitudes and frequency vectors in the sensing function templates /ligo/svncommon/CalSVN/aligocalibration/trunk/Runs/O3/H1/Measurements/FullIFOSensingTFs/ 2019-03-01_H1DARM_OLGTF_5to1100Hz_20min.xml 2019-03-01_H1_PCAL2DARM_TF_5t1100Hz_8min.xml should be used for future measurements. If you need it, my template for watching the ESD and Coil Driver DAC requests during measurement lives here /ligo/home/jeffrey.kissel/Templates/DTT H1ETMX_ActuatorSaturations.xml