A while ago Georgia and I moved the DARM offset and found that the 9 MHz RIN to DARM coupling decreases with increasing DARM offset.
Two days ago, I swept the DARM offset from 4 pm to 14.7 pm while a 70 Hz 9 MHz RIN line was on and present in DARM.  I then demodulated the line in software, plotted it as a function of DARM offset, and compared a few models to the data.  

It seems that 9 MHz RIN to DARM coupling falls like 1/DARM offset.  This rules out couplings like those explained by Kiwamu in attachment 4, which increase with increased DARM offset.
Images attached to this report
Comments related to this report
gabriele.vajente@LIGO.ORG - 08:36, Monday 04 March 2019 (47262)

The 1/DARM_offset of 1/sqrt(DCPD) coupling can be explained by considering a CONSTANT amount of 9MHzHOM coupling to the DCPDs, while the optical gain scales with the offset, such that the same amount of 9MHz RIN at the DCPD is interpreted as a different noise level in m/rHz.