Displaying report 1-1 of 1.
Reports until 17:17, Monday 04 March 2019
H1 CDS
patrick.thomas@LIGO.ORG - posted 17:17, Monday 04 March 2019 - last comment - 17:30, Monday 04 March 2019(47279)
Conlog channel list reduced to filter module and FEC channels
In order to try to eliminate channels that are changing too frequently for the data acquisition, I have reduced the monitored channel list to these. There are still 264,176 channels in this set, and the startup time remains long (more than 20 min). The queue size however has finally dropped to 0. The channel list is attached.

The FEC channels include those ending in:
DIAG_RESET
OVERFLOW_RESET
LOAD_NEW_COEFF
LOAD_CONFIG
BUILD_SVN
MSG
MSGDAQ
SDF_MON_ALL
SDF_CONFIRM
SDF_LOADED
SDF_RELOAD
SDF_SAVE_CMD

The filter module channels include those ending in:
SWSTAT
TRAMP
OFFSET
GAIN
LIMIT
SW1
SW2
RSET
SW1R
SW2R
SW1S
SW2S
Name00
Name01
Name02
Name03
Name04
Name05
Name06
Name07
Name08
Name09

The following channels are currently unmonitored:
H1:DAQ-FEC_27_LOAD_CONFIG
H1:FEC-27_BUILD_SVN
H1:FEC-27_DIAG_RESET
H1:FEC-27_LOAD_NEW_COEFF
H1:FEC-27_MSG
H1:FEC-27_MSGDAQ
H1:FEC-27_OVERFLOW_RESET
H1:FEC-27_SDF_CONFIRM
H1:FEC-27_SDF_LOADED
H1:FEC-27_SDF_MON_ALL
H1:FEC-27_SDF_RELOAD
H1:FEC-27_SDF_SAVE_CMD
Non-image files attached to this report
Comments related to this report
patrick.thomas@LIGO.ORG - 17:30, Monday 04 March 2019 (47281)
If there are other channels that we are *certain* will only be changed manually, let me know and I can add them.
Displaying report 1-1 of 1.