Simulation of point absorber effect - update

Here's another update to previous simulation of the effect of the optical path distortion (OPD) in ITMY due to the point absorber (following up on 47027 and 46952).

Simulation details:

Results:

Images attached to this report
Comments related to this report
gabriele.vajente@LIGO.ORG - 13:43, Wednesday 27 February 2019 (47162)

The two plots below show the mode content at the OMC input as a function of the point absorber position. The input power is 26 W and the modulation depth is 0.2 for 9 MHz and 45 MHz and 0.1 for 118 MHz. The first plot shows the decomposition into all modes, while the second shows the total for each order.

 

Images attached to this comment
gabriele.vajente@LIGO.ORG - 14:16, Tuesday 05 March 2019 (47305)

In the worst case scenario, with the point absorber at about 2cm from the beam center, the largest TEM9 mode has about 5 mW of power, so five times more than what initially reported in 47027. This means that (assuming all the TEM9 mode is transmitted by the OMC) we would need a RF9 RIN of about 1e-7 /rHz to explain the DARM excess noise.