CDS Maintenance Summary: Tuesday 5th March 2019

WP8108 DAQ 10GE switch reconfigure

Jonathan, Dave:

Please see alog below for details. DAQ computers were restarted twice during this upgrade. The DAQ was not reconfigured.

WP8038 h1guardian1 machine relocation

Jonathan, T.J., Dave:

the new V4 h1guardian1 machine was moved from its temporary location to its correct location. The V2 machine (old guardian) which was in this slot will get racked as h1dmt4 once we get a compatible rail kit installed.

TJ monitored the restart of the guardian nodes, there were no issues.

WP8075 DMT test machine upgrade

Jonathan, Greg, Dave:

h1dmt2 was moved from its current location to below the h1dmt0,1 stack (a slot vacated by the h1guardian1 move). This in turn frees the space for the new h1dmt4 machine.

cdsfs1 reboot

Carlos, Jonathan:

Carlos discovered issues with cdsfs1. It was updated and rebooted.

Beckhoff restarts and SDF restart.

Daniel, Dave:

Daniel restarted some Beckhoff systems and found that the SDF for C1PLC1 became unresponsive. I restarted h1sysecatc1plc1sdf to fix this.

Comments related to this report
david.barker@LIGO.ORG - 16:52, Tuesday 05 March 2019 (47317)

CNS-II GPS receivers were swapped between end stations, now Timing system is green. The surprising thing was within a minute of putting, for example, the 'EX' unit at EX, its timing status went green. I was expecting several hours of satellite locking would be needed for this to happen.

The new install table is

EX S/N 404358
EY S/N 404357

 

david.barker@LIGO.ORG - 16:55, Tuesday 05 March 2019 (47318)

Details of today's restarts

2019_03_05 10:27 h1fw2
2019_03_05 10:36 h1nds1
2019_03_05 10:38 h1fw0
2019_03_05 10:44 h1tw3
2019_03_05 10:46 h1fw1
2019_03_05 10:46 h1tw0
2019_03_05 10:48 h1tw0
2019_03_05 10:50 h1nds0
2019_03_05 10:52 h1broadcast0
2019_03_05 10:52 h1tw0
2019_03_05 10:56 h1fw0
2019_03_05 10:56 h1fw1
2019_03_05 10:56 h1fw2
2019_03_05 10:56 h1nds0
2019_03_05 10:56 h1nds1
2019_03_05 10:56 h1tw0
2019_03_05 10:56 h1tw1
2019_03_05 10:56 h1tw3
2019_03_05 10:59 h1broadcast0
2019_03_05 11:07 h1sysecatc1plc1sdf

NOTE: h1dc0 is missing from this list.

Displaying report 1-1 of 1.