corey.gray@LIGO.ORG - posted 15:59, Thursday 07 March 2019 (47360)
DAY Operator Summary

TITLE: 03/07 Day Shift: 16:00-00:00 UTC (08:00-16:00 PST), all times posted in UTC
STATE of H1: Commissioning
INCOMING OPERATOR: None
SHIFT SUMMARY:

Rode through a few earthquakes at beginning of the shift and went through the EARTH_QUAKE STATE state in SEI_CONFIG (see Jim's alog).  It was cool to toggle between this state and be able to lock AND also stay locked at POWER_30W.

ISC Locking Note:  Violin modes have been noisy lately so have been skipping the OMC_WHITENING state: 

While in NLN later, Sheila mentioned SRC1 P&Y signals are biggest out of the ASC Control signals; Sheila mentioned a boost filter might do the trick for optimizing these signals.
LOG: