Displaying report 1-1 of 1.
Reports until 22:04, Thursday 07 March 2019
H1 ISC (ISC)
craig.cahillane@LIGO.ORG - posted 22:04, Thursday 07 March 2019 (47385)
OMC ASC added to noisebudget
Added the OMC ASC controls noise projections into the live noisebudget.

Projections are done by reading in the control signal of each OMC ASC loop (Pos X, Pos Y, Ang X, Ang Y), calibrating the control signal to DARM meters like a simple pendulum zpk during an excitation, then projecting the ambient control signal into DARM noise all the time.  

Each projection is shown in attachment one.
The quadrature sum of each projection (OMC ASC) is shown as the pink curve in the second attachment.

With the live noisebudget, we'll be able to tell if OMC ASC controls noise is ever unusually high.  cool

Problem with the live noisebudget: we cannot yet look at subnoisebudgets.  So I cannot look at the four traces that make up OMC ASC in a second plot.
Images attached to this report
Displaying report 1-1 of 1.