Reports until 16:04, Friday 08 March 2019
H1 ISC
jenne.driggers@LIGO.ORG - posted 16:04, Friday 08 March 2019 - last comment - 16:49, Friday 08 March 2019(47405)
DHARD P injection

I injected bandlimited noise into H1:ASC-DHARD_P_EXC starting at about 23:55:00 UTC 8 Mar 2019, and increasing the size of the excitation by 3x at about 23:58:00 UTC, and then stopped the excitation around 00:01:00 UTC (9 Mar 2019).  Hopefully this is enough data to see if the DHARD coupling to DARM is more stationary.

EDITED to correct the time zones.

Comments related to this report
gabriele.vajente@LIGO.ORG - 16:49, Friday 08 March 2019 (47406)

At a first look, DHARD_P coupling appears to be much more stationary. Comparing to 47274:

  1. the coherence between DARM and DHARD_P during the injection is higher (see first plot)
  2. a spectrogram of DARM during the injection appears much more stationary than before (see second plot and third plot for a whitened version)

I also ran the non-stationary noise subtraction code, and confirmed that most of the noise coupling is stationary (see 4th figure). The largest non stationary contribution comes from modulation due to PRC1_P

Images attached to this comment