Displaying report 1-1 of 1.
Reports until 08:49, Monday 11 March 2019
H1 PSL (PSL)
travis.sadecki@LIGO.ORG - posted 08:49, Monday 11 March 2019 (47424)
PSL Weekly


    Laser Status:
    Front End Power is 31.97W (should be around 30 W)
    70W Output Power is 69.9W
    Front End Watch is GREEN
    70W Watch is GREEN

    PMC:
    It has been locked 2 days, 20 hr 22 minutes (should be days/weeks)
    Reflected power = 10.15Watts
    Transmitted power = 54.85Watts
    PowerSum = 65.0Watts.

    FSS:
    It has been locked for 0 days 8 hr and 25 min (should be days/weeks)
    TPD[V] = 4.294V (min 0.9V)

    ISS:
    The diffracted power is around 2.2%
    Last saturation event was 0 days 8 hours and 41 minutes ago (should be days/weeks)


    Possible Issues:

Displaying report 1-1 of 1.