46 Hz line

During today's lock we have seen a high narrow peak at 46.1 Hz. This looks to be separate from the wandering 48Hz line (seen as a lump in our DARM spectra).

Bottom plot of attached screenshot is a 0.01 Hz resolution DARM spectrum. The top plot is zoomed into the 46 Hz region: black is a reference from Feb 28, grey and yellow are from two points during today's lock, with low and high ~48Hz line activity respectively. The 46 Hz line was also present in our Feb 28, but today it is a factor of ~4 larger for sone reason.

 

I ran bruco for a quiet time during this lock, but didn't see strong coherence with anything (closest being 0.21 coherence at 46 Hz with LSC-REFL_A_RF45_I_ERR_DQ).

 

(I had run bruco at a different time, and was excited to see coherence with an end-x sus rack magnetometer, but it turns out there was a glitch in the time window I picked.)

Images attached to this report
Comments related to this report
jenne.driggers@LIGO.ORG - 11:20, Tuesday 12 March 2019 (47456)

This feels reminiscent of the Hartmann wavefront sensor camera refresh rate.  Team TCS is going to look at this as soon as they are finished with their currently-ongoing maintenance tasks.