Displaying report 1-1 of 1.
Reports until 12:02, Friday 15 March 2019
H1 SQZ (SQZ)
nutsinee.kijbunchoo@LIGO.ORG - posted 12:02, Friday 15 March 2019 - last comment - 12:52, Friday 15 March 2019(47562)
A Quick SQZ Loss Estimate

Sheila, Nutsinee

Here I plot a quick couple of data points from yesterday's measurement. A more detail analysis will come later (extracting sqz/asqz from higher averages DARM spectrum and fitting with the Monte Carlo). These sqz/asqz data points were acquired using the 10s average blrms around 1.65kHz. The loss of 40% fits the measurement pretty well (same as Livingston). We need more non linear gain to accurately determine the phase noise.

Images attached to this report
Comments related to this report
nutsinee.kijbunchoo@LIGO.ORG - 12:52, Friday 15 March 2019 (47564)

Attached a sqz/asqz vs. frequency plot.

 

Images attached to this comment