daniel.sigg@LIGO.ORG - posted 09:02, Tuesday 19 March 2019 - last comment - 17:04, Tuesday 19 March 2019(47655)
IMC Servo board swapped

The servo board for the IMC (S/N S1102626) was replaced with the modified spare (S/N S1102627). This implements E1800338-v3 and ECR E1900059.

Comments related to this report
daniel.sigg@LIGO.ORG - 11:55, Tuesday 19 March 2019 (47663)

When the spare is not a spare... The IMC wouldn't lock. I opened the original IMC servo and it has the fast option installed, whereas the spare has not; see alog 29250. The modifications were applied to the original board. Then, the original chassis was put back in.

Also, noticed that some of the modifications were already applied, see alog 31138. However, this was never propagated to the e-traveler.

daniel.sigg@LIGO.ORG - 16:34, Tuesday 19 March 2019 (47682)

Here is the comparison with the previous version measured in alog 47485.

There is a significant improvement in IMC_I. The error signal now looks like it is limited by converter noise below 2 kHz. Strangely, there is a set of peaks around 2.5 kHz that are not in IMC-L or IMC-F. There is some loss of coherence between IMC-F and IMC-L between 1 and 10 Hz. This seems again converter noise in IMC-F.

Non-image files attached to this comment
daniel.sigg@LIGO.ORG - 17:04, Tuesday 19 March 2019 (47684)

Full bandwidth spectrum.

Non-image files attached to this comment