Reports until 09:12, Tuesday 19 March 2019
H1 ISC
gabriele.vajente@LIGO.ORG - posted 09:12, Tuesday 19 March 2019 - last comment - 18:21, Wednesday 20 March 2019(47656)
Some coherences

BruCo scan here for last night lock: https://ldas-jobs.ligo.caltech.edu/~gabriele.vajente/bruco_lho_1237033818/

Some highlights:

 

 

Images attached to this report
Comments related to this report
jenne.driggers@LIGO.ORG - 10:37, Tuesday 19 March 2019 (47660)

We should check in on this again for our next lock, before we try any TCS tuning, but for at least one lock from yesterday afternoon, there is much less coherence with INP1. 

DanB points out that this time is right near a TCS CO2 power change, and the IFO was cooling down a bit, so perhaps the ASC was following in a weird way.  On the other hand, I've been suspicious about that particular frequency region for a while - some locks it seems high, while other locks it seems low.

There is a 2Hz cutoff in the INP1 ASC loops, but at higher frequency the suppression is only 40dB.  So, probably we should take a quick measurement of these loops and add some more aggressive cutoffs just in case.

terra.hardwick@LIGO.ORG - 18:42, Tuesday 19 March 2019 (47692)

The 480 Hz is a jitter peak (ID'd by Robert here and damped here); the WFS are our best witness of jitter. I had a look at a non peak time (16/03 18:00) and a peak time (19/03 11:30) and the WFS see no difference in the 476 Hz peak, suggesting a coupling change.

Images attached to this comment
jenne.driggers@LIGO.ORG - 18:21, Wednesday 20 March 2019 (47725)

Maybe I take my statement about lower coherence with INP1 back.  For several locks, even in the absence of any TCS work, we have modest coherence with INP1.  I have modified the cutoffs, see alog 47726.