Reports until 11:28, Wednesday 20 March 2019
H1 CAL (CAL)
madeline.wade@LIGO.ORG - posted 11:28, Wednesday 20 March 2019 (47695)
GDS calibration configuration and filter update and pipeline restart

M. Wade, A. Viets

I have created a new .ini file and a new filters file for the GDS calibration pipeline to go along with the gstlal-calibration-1.2.9 release. I restarted the production and redundant pipelines with this new configuration file around GPS time 1237083343.  The new configuration file is located in the calibration SVN:

aligocalibration/trunk/Runs/ER14/GDSFilters/H1GDS_1236979074.ini

The changes to the configuration include:

This configuration file also points to new a filters file, also located in the SVN:

aligocalibration/trunk/Runs/ER14/GDSFilters/H1GDS_1236979074.npz

This filters file points to the most recent modelparams file:

aligocalibration/trunk/Runs/O3/H1/params/modelparams_H1_20190316.py

I've attached some plots of data calibrated with these filters.  The first plot is a comparison of the ASD produced from the GDS calibration pipeline using these filters and an ASD produced from the CAL-DELTAL_EXTERNAL channel.  The second plot is a ratio of these two ASDs.  The third plot is a  plot of the statevector for this time period.

Images attached to this report