Displaying report 1-1 of 1.
Reports until 11:11, Wednesday 20 March 2019
H1 AOS
robert.schofield@LIGO.ORG - posted 11:11, Wednesday 20 March 2019 (47718)
Jitter peaks increased with power increase

Anamaria, Robert

The plot shows that several peaks are more visible in DARM after the power increase. Most obvious are 483 Hz (turning mirror before rotation stage – was damped), 820 Hz (possibly the optic right after the PMC – hasn’t been damped yet), and two un-identified peaks that had become visible after the recent sensitivity improvements, and that increased in amplitude with the power increase, at about 59 and 70 Hz. We will start looking for the sources of these latter peaks.

Non-image files attached to this report
Displaying report 1-1 of 1.