Reports until 16:05, Tuesday 27 November 2012
H1 AOS
douglas.cook@LIGO.ORG - posted 16:05, Tuesday 27 November 2012 (4776)
BSC2 BS cartridge positions_LHO location
(Doug, Jason, Travis)
BS position with dummy mass installed in "bang" on. The glass mass will shorten the distance by 1.46mm due to thickness difference, but is still within the 1.46mm +/-3.0mm tolerance.
Prior error due to a Teflon transport stop being in place during the previous measurements.