ISC_LOCK guardian node not connecting to H1:ASC-POP_X_RF_Q3_GAIN

Jamie, Sheila, Dave, Jonathan,

ISC_LOCK was not connecting to H1:ASC-POP_X_RF_Q3_GAIN. From h1guardian1 was was able to connect to this channel with no problems when running caget manually in a login shell. Sheila forced a reconnection of this node's EPICS channels and was able to proceed past this point.

We noticed that htop on h1guardian1 was looking very different to restart times. After a reboot all 40 cores were evenly loaded at about 50%. Now many are in the 70-90% range, and this shifts constantly over the cores.

Jonathan installed his system diagnostics EPICS IOC on the guardian machine this afternoon. We will monitor this via StripTool over the next few days, and add these channels to the DAQ next Tuesday. I would also like to reboot h1guardian1 next tuesday so we can monitor the core usage evolution.

Comments related to this report
david.barker@LIGO.ORG - 16:50, Friday 22 March 2019 (47778)

htop core usage shown

Images attached to this comment