Squeezer Takes H1 Out Of OBSERVING...sort of

attached are photos of the Guardian Nodes which I took action on.

Images attached to this report
Comments related to this report
nutsinee.kijbunchoo@LIGO.ORG - 23:32, Sunday 24 March 2019 (47834)

Does ISC_LOCK not take SQZ_MANAGER to its nominal state anymore? Or did ISC_LOCK requested SQZ_MANAGER nominal state and failed? What's in Inject_squeezing state in the ISC_LOCK?

If ISC_LOCK requested SQZ_MANAGER to go to nominal state but failed for got stuck, can I have more details of how it fails next time this happens? Including guardian log, screenshots, would be helpful for improving squeezer automation.

corey.gray@LIGO.ORG - 00:39, Monday 25 March 2019 (47836)SQZ

ISC_LOCK takes the SQZ _Manager to its nominal state during normal locking, but with what happened tonight (would we call this the "Squeezer losing lock" or something else?), the ISC_LOCK & ALIGN_IFO were transitioned to "NOT OK" states, when the Squeezer did what it did.  

Luckily I was able to get the SQZ Guardian nodes mentioned above to their nominal state.  Otherwise,  ISC_LOCK & ALIGN_IFO would have remained "Not OK" and would prevent OBSERVING.  Alternatively, if one is comfortable with changing the  ISC_LOCK & ALIGN_IFO scripts, I reckon there must be a way to break this remaining connection they have to the squeezer.

Anyway, when I looked at SQZ_MANAGER and SQZ_LO_LR, they were not actively doing anything according to their logs.  SQZ_LO_LR was down and staying there.  After I (1) tried getting it to its nominal state, and then (2) getting SQZ_MANAGER to its nominal state, then   ISC_LOCK & ALIGN_IFO were back to being OK.  

Since this was easy to recover from, maybe it's good to have it go down in this way?  Mainly because recovery was fairly straightforward?  And we also get a heads up that Squeezer's state has changed.

Oh, and good idea about posting more info.  Attached is screenshot showing all the logs of pertinent guardian nodes from this event.  Now that I look at them, it looks like ISC_LOCK & ALIGN_IFO probably did not take us out...but they point the way to SQZ since they give the messages when they were listed as "not ok" (but their logs don't show anything until the very end when I go back to Observing). 

I reckon it's the SDF  diffs from the squeezer which took us out of OBSERVING.

Hope this helps!

Images attached to this comment
corey.gray@LIGO.ORG - 00:51, Monday 25 March 2019 (47837)SQZ

Oh, and the other thing from the screenshots is that you can see ISC_LOCK definitely does not do anything to the SQZ_MANAGER when this happened.  (but ISC_LOCK & align_ifo were listed as NOT OK....and this would not have let us return to Observing until we fixed their situation with the SQZ or edited their scripts).