Displaying report 1-1 of 1.
Reports until 16:05, Tuesday 26 March 2019
H1 CAL (CAL)
richard.savage@LIGO.ORG - posted 16:05, Tuesday 26 March 2019 (47858)
Pcal Working Standard to Gold Standard responsively ratio values for the start of O3

NikoL, SudarshanK, RickS

We've analyzed the measurements made to date with our updated Pcal laser power calibration standards (see LIGO-T1800359-v2 and LIGO-G1900393-v4).

The method used to arrive at the O3 starting values is described in LIGO-T1900134-v2.

The WS/GS responsivitiy ratios ("Final values" in table) at in the attached table.

 

Non-image files attached to this report