Sheila, JeffK, Betsy
With the IFO set to Down after a fresh lockloss, we tackled setting the SAFE SDF files across all SUS, LSC, ASC, etc files (in prep for lsc, tcs, sqz, guardian to all be restarted this am). We generally accepted all things that guardian had newly set this morning, accepted all new Damping matrices settings, reverted some A2L settings from an errant script run over the weekend, and Sheila hand accepted/reverted a handful of things that were not well logged but that she thought seemed appropriate.
We found new ETMY_M0_TEST_OFFSETS changed Feb 13, but not logged. We decided to leave them, but are unsure of where they came from. See snapshot.
Once IMC setting files were sorted, Jeff set the IMC to OFFLINE for the VCO cards to be pulled (scheduled maint item).
I accidentally ACCEPTED 3 settings on the HAM2 ISI OBSERVE file, so those will pop back up in OBSERVE and will need ACCEPTING to get them back to the correct state.
We ignored all Beckhoff SDF files since Daniel had already started work on them and didn't want us changing the files.