Displaying report 1-1 of 1.
Reports until 14:01, Tuesday 26 March 2019
H1 PSL (PSL)
cheryl.vorvick@LIGO.ORG - posted 14:01, Tuesday 26 March 2019 (47892)
PSL Weekly Report - FAMIS 11005


    Laser Status:
    Front End Power is 31.67W (should be around 30 W)
    70W Output Power is 70.37W
    Front End Watch is GREEN
    70W Watch is GREEN

    PMC:
    It has been locked 0 days, 0 hr 0 minutes (should be days/weeks)
    Reflected power = 9.829Watts
    Transmitted power = 54.48Watts
    PowerSum = 64.31Watts.

    FSS:
    It has been locked for 0 days 0 hr and 0 min (should be days/weeks)
    TPD[V] = 3.516V (min 0.9V)

    ISS:
    The diffracted power is around 2.1%
    Last saturation event was 0 days 0 hours and 5 minutes ago (should be days/weeks)


    Possible Issues:  This looks good, up time is reflecting the end of Maintenance.

 

Displaying report 1-1 of 1.