Displaying report 1-1 of 1.
Reports until 11:07, Thursday 28 March 2019
H1 CDS (CAL, FRS)
jeffrey.kissel@LIGO.ORG - posted 11:07, Thursday 28 March 2019 - last comment - 13:15, Thursday 28 March 2019(47981)
Problems remain with SDF Diff Comparison with Very Small vs. Very Big Numbers
J. Kissel

SDF is still having problems comparing / checking very small or very large EPICs records. This is usually exposed in the calibration group's "epics records" i.e. DARM loop model parameters at a reference time used to compute time-dependent correction factors, which are typically very small or very large -- in the 10^-17 levels or 10^+18 levels (see attached). It's unclear *when* exactly the claimed differences happen (maybe when the .snap comparison file is changed from safe to OBSERVE? Or maybe because when you *accept* the diffs, they're written at a lower precision than that comparison is made?), but it's something we're having to constantly reconcile before every observation stretch these days. 
Images attached to this report
Comments related to this report
stuart.aston@LIGO.ORG - 13:15, Thursday 28 March 2019 (47991)GRD, OpsInfo
We are also seeing similar issues at LLO too with the l1calcs model being most egregious (for example see LLO aLOG entries: 44427, 44673, 44310 and 44292).