Unknown cause. I had stepped out of the control room and noticed it was in Commissioning upon return. No SDF diffs. There was a notification on Verbal Alarms of an EX saturation at 12:10 UTC. I had earlier noticed the scheduled injection running at 12:00 UTC in the DARM spectrum. Lock is now 10 hours young.
There is a distinct line of glitches noticeable in the DMT Omega FOM that lines up approximately with the loss of Observing.
The IFO Guardian node reported SDF diffs at that time. DIAG_SDF node reported susitmy, susetmx, and susetmy diffs with 15 seconds of each other then.
2019-03-29_12:11:14.085423Z DIAG_SDF [RUN_TESTS.run] USERMSG 0: DIFFS: susitmy: 1
2019-03-29_12:11:27.206766Z DIAG_SDF [RUN_TESTS.run] USERMSG 1: DIFFS: susetmx: 1
2019-03-29_12:11:31.148649Z DIAG_SDF [RUN_TESTS.run] USERMSG 2: DIFFS: susetmy: 1