Displaying report 1-1 of 1.
Reports until 13:00, Thursday 28 March 2019
H1 AOS (DetChar)
reed.essick@LIGO.ORG - posted 13:00, Thursday 28 March 2019 - last comment - 10:19, Friday 29 March 2019(47988)
DetChar Safety Injections scheduled at LHO for 23:00:00 PDT 28 March 2018
These injections are scheduled to begin at 23:00:00 PDT 28 March 2018, the first injection should occur at 23:00:10 PDT 28 March 2018, and the entire excitation should last only 91 sec.

The expected GPS times of all these injections can be found in GraceDb via: https://gracedb.ligo.org/search/?query=H1+Test+HardwareInjection+gpstime%3A+1237874418+..+1237874510+HWINJREQ&query_type=E&results_format=S
Comments related to this report
evan.goetz@LIGO.ORG - 14:57, Thursday 28 March 2019 (48005)
Schedule file was updated and INJ_TRANS was reloaded to pick up this injection. Unfortunately, this caused H1 to drop from observing.
reed.essick@LIGO.ORG - 10:19, Friday 29 March 2019 (48033)DetChar
The injections were successful. I've attached a CSV file with the expected injection paramters. They can also be discovered in GraceDb via: https://gracedb.ligo.org/search/?query=Test+H1+HardwareInjection+HWINJOK+1237874418+..+1237874518&query_type=E&results_format=S

Non-image files attached to this comment
Displaying report 1-1 of 1.