Reports until 14:54, Friday 30 November 2012
LHO VE
kyle.ryan@LIGO.ORG - posted 14:54, Friday 30 November 2012 (4808)
CP7 dewar exhaust piping vibrating
Exhaust flow through piping is sustaining a mechanical vibratory resonance -> Increased flow by adjusting regulator 1 turn CCW -> this increase flow stopped the vibrations but will result in a lower dewar vapor pressure which will cause the nominal %open of the LLCV to increase -> trial and error should produce a happy medium -> if not, then piping will have to be clamped differently