SDF diffs after relocking

Lost lock, relocked with minimal touching, but on getting to NLN, there is an SDF diff. The OSC3 to AO3 element on the LSC outpu matrix is set to 1. Not sure what this means, OSC3 and AO3 aren't exactly descriptive. Have accepted and back to observing.

Images attached to this report
Comments related to this report
jenne.driggers@LIGO.ORG - 07:48, Monday 01 April 2019 (48107)

Hmmm. This should have been set to 0 by the AWG_LINES guardian.  Anyhow, since we're out of Observing for sweeps, I have set it to zero and accepted this in SDF.  There wasn't an excitation going, and the analog enable switch was off, so there's no problem with this having been accepted, but it's now set to zero.