Displaying report 1-1 of 1.
Reports until 00:28, Friday 05 April 2019
H1 IOO (IOO)
cheryl.vorvick@LIGO.ORG - posted 00:28, Friday 05 April 2019 (48185)
IM alignment jump in IM1, IM2, and IM3, on Feb. 12, 2019

There was an event on Feb. 12, starting just after 19:31 UTC, that strongly shook the IMs in HAM2, and caused ISI and optics in HAM2 to trip, and caused alignment shifts in the IMs.  Plots attached show length, pitch, and yaw signals, and OSEM OUT signals, along with guardian states of each IM and HAM2 HEPI and ISI.

optic dof change
im1 length 0.8um
im1 pitch -81.2urad
im1 yaw -12.1urad
im2 length -0.5um
im2 pitch 48.2urad
im2 yaw 6.4urad
im3 length -0.2um
im3 pitch 56.8urad
im3 yaw -11.1urad

Adding this to FRS Ticket 4698.

Images attached to this report
Displaying report 1-1 of 1.