Reports until 21:43, Wednesday 03 April 2019
H1 General
Link
cheryl.vorvick@LIGO.ORG -
posted 21:43, Wednesday 03 April 2019
(48220)
OPS Mid-Shift Update:
00:52:37 UTC
- went out of Observe for calibrations
completed calibration measurements using JeffK's instructions
addressed violin modes that rang up using Rahul's instructions
found one violin mode gain in SDF, cleared
found 12 CALCS channels in SDF, cleared
03:25:38 UTC
- put H1 back in Observe
03:31:25 UTC
- H1 kicked out for a violin mode gain
stayed out to check all violin mode gains were not monitored
found some on all 4 optics
03:44:38 UTC
- put H1 back in Observe, while out of Observe, no H1 changes
SDF snapshots attached show everything I accepted or changed to Not Monitored
I un-monitored all TRAMP and GAIN channels for violin modes 1 through 20, all optics, (with 99% confidence that I didn't miss one)
two trend plots of violins, showing ring up with excitation, and ring down after damping applied
dtt plots of fundamental and second harmonic violin modes
green is at the max, before I applied damping to the modes that had rung up and/or had damping off
red is after the damping had been on for a while
Images attached to this report