Displaying report 1-1 of 1.
Reports until 17:14, Friday 05 April 2019
H1 SQZ
sheila.dwyer@LIGO.ORG - posted 17:14, Friday 05 April 2019 - last comment - 20:10, Friday 05 April 2019(48274)
squeezer guardian changes

Earlier the squeezer unlocked and took us out of observing. 

Changes to SQZ_MANAGER:

Images attached to this report
Comments related to this report
daniel.sigg@LIGO.ORG - 19:47, Friday 05 April 2019 (48277)

Loosing that much power through the SHG is a telltale sign that the laser has gone multi-mode. What about the pump power in the OPO? And on the REFL detector? Is it low too? The CLF could also be affected. Not sure, how useful it is to continue running with the squeezer in this configuration.

sheila.dwyer@LIGO.ORG - 20:10, Friday 05 April 2019 (48280)

Daniel-

Agreed that this could be multi moving and we should try to get away from it.  the SHG trans increased again, and the normalized power is only 0.8 at max, so this isn’t as drastic as it sounds.  We are getting around 2dB of squeezing according to the BLRMS.

Displaying report 1-1 of 1.