Displaying report 1-1 of 1.
Reports until 09:50, Tuesday 09 April 2019
H1 PSL
jason.oberling@LIGO.ORG - posted 09:50, Tuesday 09 April 2019 (48336)
PSL Maintenance (WP 8154 and FAMIS 10705)

35W FE Pump Diode Operating Current Increase (WP 8154)

This morning I increased the operating currents of the pump diodes for the 35W FE; since this is the 1st adjustment in many months, I also tweaked the pump diode operating temperatures.  All adjustments were performed with the ISS OFF.  The changes are outlined in the table below:

  Operating Currents (A) Operating Temperatures (°C)
Old New Old New
D1 47.0 47.4 26.5 26.5
D2 47.0 47.4 22.3 22.3
D3 44.0 44.4 26.8 26.8
D4 44.0 44.4 26.7 26.8

The FE is now outputting 32.3W and the ISS is back ON; a screenshot of the PSL Beckhoff FE screen is attached for future reference.  This completes LHO WP 8154.

Edit: Forgot to mention that when turning the ISS back ON, I had to adjust the reference signal to account for the increased power out of the PSL.  The old value was -2.06V, the new value is -2.08V, and the diffraction percentage is ~2.2%.  This change was accepted in SDF.

Weekly Power Watchdog Reset (FAMIS 10705)

The PSL power watchdogs were reset at 16:30 UTC (9:30 PDT).  This completes FAMIS 10705.

One Other Item

While doing the above, I noticed that the FSS RefCav TPD had fallen from Ed and I's adjustment from last week; it had fallen from ~4.2V to ~2.9V.  Seeing this, I gave the beam alignment a quick tweak.  The RefCav TPD is now reading ~3.7V.  We will continue to monitor this.