Reports until 16:27, Thursday 11 April 2019
H1 ISC
sheila.dwyer@LIGO.ORG - posted 16:27, Thursday 11 April 2019 (48425)
noise budget injections, ADS YAW5 gain increased, squeezer guardian indices updated

We were out of observing for noise budget injections from 19 UTC until 23:10 UTC. We used 4 hours of commissioning time for this. 

We lost lock right away when I accidentally made an injection while ADS was on.  1239044614  We got all the standard noise budget injections we make, with a couple of additions to the normal set: LSC, ASC (added INP1 and updated some of the injections for DC centering loops), jitter, intensity, and two frequency injections to cover the down conversion of frequency noise around the OMC dither lines and normal frequency noise coupling. 

Also during this time, I increased the gain of the ADS YAW5 (ITMY spot position to PRM) loop by 10dB, since this was fine I have put it into the ISC lock guardian.  

I have also loaded the squeezer guardian, yesterday I compared our code to LLO and changed the names and numbers of some states so that we would be more parallel to their names and numbers. The old and new mappings are in the attached text file.

 

Non-image files attached to this report