Displaying report 1-1 of 1.
Reports until 12:31, Monday 15 April 2019
H1 PSL (PSL)
corey.gray@LIGO.ORG - posted 12:31, Monday 15 April 2019 - last comment - 09:25, Tuesday 16 April 2019(48502)
PSL Weekly Report (FAMIS #11008)

    Laser Status:
    Front End Power is 32.31W (should be around 30 W)
    70W Output Power is 70.23W
    Front End Watch is GREEN
    70W Watch is GREEN

    PMC:
    It has been locked 0 days, 0 hr 0 minutes (should be days/weeks)
    Reflected power = 9.893Watts
    Transmitted power = 54.94Watts
    PowerSum = 64.83Watts.

    FSS:
    It has been locked for 0 days 12 hr and 50 min (should be days/weeks)
    TPD[V] = 3.965V (min 0.9V)

    ISS:
    The diffracted power is around 2.2%
    Last saturation event was 0 days 13 hours and 51 minutes ago (should be days/weeks)


    Possible Issues:  Looks OK.

Comments related to this report
peter.king@LIGO.ORG - 15:36, Monday 15 April 2019 (48507)
This is just a comment in passing.  I find it strange that every time the PSL weekly report script is run
it almost always reports that either the FSS or PMC has only been locked for a few hours.  Many times it
reports numbers less than 6 or 12 hours, when anecdotally both remain locked for much longer.
thomas.shaffer@LIGO.ORG - 09:25, Tuesday 16 April 2019 (48528)PSL

The script will look at the channels: H1:PSL-{PMC/FSS}_RELOCK_{DAY/MIN/HOUR}

Is these channels are reporting false information, the script can be changed to look at something more accurate.

Displaying report 1-1 of 1.