11:45 Lockloss occurred without Verbal Alarm warning as it seems that VA had stopped.
12:25 FIrst re-lock attempt failed at ENGAGE_ASC_FOR_FULL_IFO - "H_T_T_S"
RF 90 started to increase, leading into the loss, causing a dip in RF 18
Second attempt is looking better. ASC loops took approx 6 minutes to converge.
13:09 increased H1:LSC-REFL_SERVO_IN1GAIN up 3dB from 9 to 12 at NLN upon RF 9/18 trace settling at 47 cts (on Craig's tutelage)
ETMY violin modes 1 and 6 elevated but ringing down. I increased the gain on Mode 6 to .6 from 0
13:10 H1 back to Observing
https://ldas-jobs.ligo-wa.caltech.edu/~lockloss/index.cgi?event=1240143964