Reports until 16:24, Thursday 25 April 2019
H1 AOS
sheila.dwyer@LIGO.ORG - posted 16:24, Thursday 25 April 2019 - last comment - 17:41, Wednesday 08 May 2019(48767)
a couple of hours of commissioning

We took about 4 hours of time for commissioning today:

A quick summary of the cross over measurements (Jenne, Sheila):

Motivation:

Measurement:

Images attached to this report
Comments related to this report
sheila.dwyer@LIGO.ORG - 17:41, Wednesday 08 May 2019 (49127)CAL, SUS

Here are the measurements from this time plotted against a pyDARM model.  

The blue line is a model of what the L2 LOCK IN1/IN2 measurement is expected to look like based on the pyDARM model of the actuators.  The green dots are measurements of this crossover made on April 3rd, they are plotted here just so that you can see some higher frequency data (we didn't retake any higher frequency measurements)

These measurements could be explained by a coupling of the length drive to either the angle of the optic through a mechanical coupling or to the angular sensor, the ASC loop then tries to actuate in response, but there is a coupling from angle back to length because we are not doing a nice job of a frequency dependent angle to length decoupling.  When we turned off the A2L decoupling, by setting the scalar gains to 0 but not running the ADS so that the spot positions stayed in their normal positions.  In principle, a more accurate frequency dependent A2L decoupling could be used to reduce this effect.

In 47824 and 47982 we saw that when we turned off the L2A decoupling filters, which increased the gain of the PUM by getting rid of the L2A2L coupling that comes from having our spots well off center and not routing the L2A output through the A2L decoupling, we had a crossover instability around 8 Hz.  This was solved by turning off the 4.5Hz boost in the PUM lock filter, which doesn't make complete sense but it is plausible given these emasurements that the problem with the boost was caused by these angular cross couplings, especially if there are features that are not resolved in this measurement.

Non-image files attached to this comment