TITLE: 04/27 Eve Shift: 23:00-07:00 UTC (16:00-00:00 PST), all times posted in UTC STATE of H1: Lock Acquisition INCOMING OPERATOR: Jeff SHIFT SUMMARY: Spent entire shift trying to relock. Did not get past ENGAGE_SOFT_LOOPS. - Winds were high in the beginning of the shift. Tried initial alignment with WINDY_NO_BRSY, since the BRSY was damping for a long time. - SUS SRM watchdog tripped 3 times during the shift. - Could not get IR to lock on X arm in initial alignment. Tried twice, the second time after the wind came down. Skipped and continued with rest of initial alignment. - SRM was way off in yaw, according to witness sensors. Had to move it back to get SRC to converge in initial alignment. - Have gotten as far as ENGAGE_SOFT_LOOPS by setting H1:ASC-SRC1_Y_GAIN to 0 in ENGAGE_ASC_FOR_FULL_IFO before it lost lock. - Was able to improve signals by adjusting SRM with ASC SRC gain off in ENGAGE_SOFT_LOOPS, but not enough to keep it from driving off when setting the gain back. - Started adjusting PRM in ENGAGE_SOFT_LOOPS. Looked like I was making progress, but then lost lock.