TITLE: 04/28 Day Shift 15:00 – 23:00 (08:00 -16:00), all times posted in UTC
STATE of H1: Aligning
INCOMING OPERATOR: Patrick
SHIFT SUMMARY: Started out unable to get through ACQUIRE_PRX in initial alignment. With Keita’s help, I was able to adjust PRM to get H1:ASC-POP_A_NSUM_OUTPUT high enough to get to WFS_CENTERING_PRX. Then after more searching we reverted changes to the SUS HTTS SDF, which allowed us to get through initial alignment. Then misaligning SR2 at the beginning of the lock sequence was causing SUS_SRM to trip because the damping filters were all turned off. We turned those on, and then I was not able to get past FIND_IR because the COMM_OFFSET frequency had changed from -200 to -37,500 and the offset search was too far away to find it. I then lost lock from OFFLOAD_DRMI_ASC several times due to (I’m guessing) SRM being badly misaligned. Leaving it with Patrick, who is starting an initial alignment.
LOG:
15:00 (08:00) Start of shift
19:56 (12:56) Robert to LVEA -- take picture of chamber
20:00 (13:00) Robert back from LVEA
23:00 (16:00) End of shift