Quick SDF survey in DOWN, just after NLN lockloss

We just broke lock for maintenance, and TJ caught the guardian to hold it in READY just after it had completed DOWN and PREP_FOR_LOCKING.  Before anything else changed, I did a quick survey of all the SUS and ISC SDFs and accepted all of the diffs that seemed appropriate.  Since some seismic state things had been changed with the seismic guardian, I did not accept any diffs for SEI.  But, other than SEI everything is pretty well reconciled.  I hope that this will help in case we get some kind of power outage or accidental computer reboots, or in a case like this weekend where we got stuck due to some subtle filter switches that were off.